This revision list only contains changes to the Equipment Hub service itself. There may be related changes that are in the Change Log that may also be of interest.
Version | Release | Reference Number | Description | Currently Supported |
3.4.3.0 | 24.04.10 | 3394 | Added support for the IBA myQA Daily device. | Yes |
3.4.2.2 | 23.11.01 | 3275 | Fixed issue where Equipment Hub crashes when pulling data from QA Beam Checker where the field size uses x in place of a comma. | Deprecated |
3.4.2.1 | 23.09.06 | 3210 | Added support to upload HTML files such as the Philips IQ reports. | Deprecated |
3.4.2.0 | 23.04.15 | 3050 | Added support for regular expressions when setting up File Uploader filters using DICOM tags to filter images. | Deprecated |
3.4.1.5 | 23.03.01 | 3022 | Added support for batching IC profiler PRM files together for the profile comparison test. | Deprecated |
3.4.1.4 | 22.12.15 | 2894 | Resolved issue where if the results file for the PTW Quickcheck were missing that the Schedule settings would be left blank. The treatment unit information is now cached ensuring that a blank treatment room is not inadvertently saved when other Schedule settings are edited. | Deprecated |
3.4.1.3 | 22.09.07 | 2845, 2846 | Improved Equipment Hub Installer to check the Windows and .NET version before any changes are made. If the version is too low, the install will be aborted. | Deprecated |
3.4.1.2 | 22.08.24 | 2796 | Added support for absolute baselines when using Daily QA 3. This is the last version that supports Windows Server 2012 R2. | Deprecated |
3.4.1.1 | 22.08.24 | 2822 | Fixed issue exporting data from Daily QA 3 SQL databases. | Deprecated |
3.4.1.0 | 22.06.22 | 2102 | Added File Uploader feature to Equipment Hub to automate the upload of files for image analysis. | Deprecated |
3.4.0.0 | 22.04.13 | 2648 | Updated Equipment Hub web socket Server to the most recent Web Sockets version 4.x. Prior versions of Equipment Hub connected to the https://tqa-eqhub.imageowl.com/ endpoint. This version and newer versions will connect to the https://tqa-eqhub2.imageowl.com/ endpoint. | Deprecated |
3.3.1.0 | 22.01.12 | 2492 | Updated the web sockets library on Equipment Hub server to avoid connection issues some customers were seeing, changed functionality to ignore QA Beamchecker results marked as omit, and upon install sets Windows recovery options to restart the Equipment Hub service on all failures. | No |
3.3.0.0 | 21.07.14 | 2432 | TLS 1.2 is now supported on Equipment Hubs 3.3.0.0 and higher. This is the last version of Equipment Hub that works with Windows 7. | No |